Description: Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2. 100% insured shipping: A guarantee for your purchases ..
Description: Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2. 100% insured shipping: A guarantee for your purchases..
Description: Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Push-in connection. 100% insured shipping: A guarantee f..
Description: Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection. 100% insured shipping: A guarantee f..
Description: Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection. 100% insured shipping: A guarantee f..
Description: Ex i temperature measuring transducer: Converts signals from resistance thermometers installed in Ex areas and transmits a 0/4-20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, spring-cage terminal blocks. 100% insured shipping: A guarantee for your purcha..
Description: Repeater power supply and input isolating amplifier, HART. Transfers supplied or active 0/4 - 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 according to IEC 61508. 100% insured shipping: A guarantee for your purchases Express delivery: Worldwide deli..
Description: Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission and wide range power supply, SIL, Push-in connection 100% insured shipping: A guarantee for your purchases Express delivery: Worldwide delivery by DHL express courier..
Description: Output signal conditioner, HART. Isolates and transmits 0/4-20 mA signals to a load (I/P converters, control valves, displays). Electrical 3-way isolation, wire break recognition, SIL 2 in accordance with IEC 61508, Push-in connection. 100% insured shipping: A guarantee for your purch..
Description: Ex i measuring transducer power supply and input signal conditioner, HART-transparent. Transfers supplied or active 0/4¦20 mA electrical isolation signals from the Ex area to two loads in the safe area. 4-way electrical isolation, Push-in connection, SIL, PL. 100% insured shipping: A ..
Description: 2-channel Ex-i NAMUR isolation amplifier with wide-range power supply for proximity sensors and switches. Every channel has a relay with PDT contact as a signal output. Line fault detection (LFD), 3-way isolation, SIL 2. 100% insured shipping: A guarantee for your purchases Express ..
Description: NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using relay output (PDT). Line fault detection (LFD), galvanic 3-way isolation, SIL 2, with push-in connection. 100% insured shipping: A guarantee for your purchase..
Description: NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, Push-in connection. 100% insured shipping: A guarantee f..
Description: NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection. 100% insured shipping: A guarantee for your ..
Description: NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection. 100% insured shipping: A guarantee for your..
Description: 2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2. 100% insured sh..
Description: Temperature transducer, converts signals from resistance thermometers and resistors into 0/4 - 20 mA signals. Freely programmable, 3-way electrical isolation. 100% insured shipping: A guarantee for your purchases Express delivery: Worldwide delivery by DHL express courier..
Description: Temperature transducer, converts signals from thermocouples and linear mV sources into 0/4-20 mA signals. Freely programmable, 3-way electrical isolation, custom-configured. 100% insured shipping: A guarantee for your purchases Express delivery: Worldwide delivery by DHL express cou..
Description: Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4¦20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3, PL. 100% insured shipping: A g..
Description: Programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL. 100% insured shipping: A guar..
Description: Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL, PL. 100% insured shipping: A..
Description: Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4¦20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, screw connection, SIL, PL. 100% insured shipping: A guarantee for yo..
Description: Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4¦20 mA electrically isolated signals from the field to two loads. 4-way electrical isolation, Push-in connection, SIL, PL. 100% insured shipping: A guarantee for ..
Description: Universal termination carrier for connecting 16 MACX Analog Ex i signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection) 100% insured shipping: A guarantee for your purchases Express delivery: Worldwide delivery by DHL express courier..
Description: Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, , line fault transparency, error message output, up to SIL 3 according to IEC 61508, screw connection 100% insured shipping: A guarantee for..
Description: Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, , line fault transparency, error message output, up to SIL 3 according to IEC 61508, Push-in connection 100% insured shipping: A guarantee f..
Description: Plug for cold junction compensation for thermocouples, for safe switching of limit values, in combination with MACX ...-T-UI... temperature transducers. 100% insured shipping: A guarantee for your purchases Express delivery: Worldwide delivery by DHL express courier..
Description: Plug for cold junction compensation for thermocouples, for safe switching of limit values, in combination with MACX ...EX-T-UI... temperature transducers. 100% insured shipping: A guarantee for your purchases Express delivery: Worldwide delivery by DHL express courier..
Description: Assembled shielded round cable; connection 1: Single wires (9-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 9-position); cable length: 0.5 m 100% insured shipping: A guarantee for ..
Description: Assembled shielded round cable; connection 1: Single wires (9-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 9-position); cable length: 1 m 100% insured shipping: A guarantee for yo..